20 Flips | 1 Magazine | 3 Followers | @amoreno2000 | Keep up with a moreno on Flipboard, a place to see the stories, photos, and updates that matter to you. Flipboard creates a personalized magazine full of everything, from world news to life’s great moments. Download Flipboard for free and search for “a moreno”

Basic Impulse Insulation Levels (BIL)

The Basic Impulse Insulation Levels refers to the ability of electric equipment such as transformers to withstand lightning surges. When lightning …

Testing Procedures for HV Voltage Transformers

Content:<p>1. Equipment required<p><i>Following equipment is necessary to perform testings:</i><p>Polarity test kit<br>• Megger 500-5000V<br>• Ohmmeter<br>• Multimeter<br>• Autotransformers …

(Protection) Relay Guides

Protection Relays<p>The relay is a well known and widely used component. Applications range from classic panel built control systems to modern inrefaces …

Torque Of Three-Phase Induction Motor Explained

Introduction to motor torque<p>The <i>rotating force</i> that a motor develops is called <i>torque</i>.<p>Due to the <i>physical laws of inertia</i>, where a body at rest tends to …

6 Factors Influencing Requirements for a Good Grounding System

Six Requirements To Consider<p>In an industrial plant or other facility that requires a grounding system, one or more of the following <b>must be carefully</b> …

Sizing and Protection of the Neutral Conductor (1)

Introduction<p><b>Sizing (c.s.a.)</b> and the <b>protection</b> of the neutral conductor, apart from its current-carrying requirement, depend on several factors, …

Electric Guitar

Why is continuous on-line monitoring of partial discharge in the switchgear necessary? | EEP

<b>electrical-engineering-portal.com</b> - Not sure? You know that periodical maintenance test like partial discharge test can still leave switchgear in …

Online Life

Equipotential Bonding For Metal Installations

Design of the earth-termination system for equipotential bonding<p>The electrical low voltage consumer’s installation requiring certain earthing …

How to get rid off the harmonics in electrical system?

Nothing good from harmonics…<p>The subject of harmonics is also a contributory factor in electrical noise I already wrote few days ago (Cable spacing as …

Electric Guitar

Electrical Thumb Rules You MUST Follow (Part 1)

Electrical Thumb Rules For:<p>Cable Capacity<p><b>For Cu Wire Current Capacity (Up to 30 Sq.mm) =</b> 6X Size of Wire in Sq.mm<br>Ex. For 2.5 Sq.mm = 6×2.5 = 15 Amp, …

Electrical Thumb Rules You MUST Follow (Part 2)

• For Sinusoidal Current: <b>Form Factor =</b> RMS Value/Average Value = 1.11<br>• For Sinusoidal Current: <b>Peak Factor =</b> Max Value/RMS Value = 1.414• <b><br>Average Value of</b> …

Electrical Thumb Rules You MUST Follow (Part 3)

Continued from second part: Electrical Thumb Rules You MUST Follow (Part 2)<p>Size of Capacitor for Power Factor Correction<p><b>For Motor</b><p>Size of Capacitor = …

Electrical Thumb Rules You MUST Follow (Part 4)

Eight rules to follow:<p>1. Substation Capacity and Short Circuit Current Capacity<p><b>As per GERC</b><p><b>Voltage</b><p><b>Sub Station Capacity</b><p><b>Short Circuit Current</b><p>400 KV<p>Up to …

Arduino

Electrical Thumb Rules You MUST Follow (Part 5)

Eight rules to follow:<p>1. Standard Size of Transformer (IEEE/ANSI 57.120)<p><b>Single Phase Transformer</b><p><b>Three Phase Transformer</b><p>5KVA, 10KVA, 15KVA, 25KVA, …

Arduino

Impact of Floating Neutral in Power Distribution

Originally posted on Electrical Notes & Articles:<br>Introduction: If The Neutral Conductor opens, Break or Loose at either its source side (Distribution …

Electrical Preventive Maintenance of Air Circuit Breakers

Recommended minimum practice for preventive maintenance<p>Insulation //<p><i>Remove and clean interphase barriers.</i> Clean all insulating materials with vacuum …

Home Improvement

Overvoltages Caused by Lightning

The Impacts of Lightning<p>Overvoltages of <i>atmospheric origin</i> arise from uncontrollable sources and their severity for the load depends on many …

Weather

An example how to calculate voltage drop and size of electrical cable

Input information<p>Electrical details:<p>Electrical load of <b>80KW</b>, distance between source and load is <b>200 meters</b>, system voltage <b>415V three phase</b>, power …

4 Motor Designs Identified In NEMA MG1

It’s all about performance…<p>Performance requirements for various types of induction motors for use on <b>standard sinewave power supplies</b> are identified …